Across the European Union, every new building has had to be nearly zero-energy (nZEB) since the end of 2020: a building with very low energy use, covered in part by renewable sources. That is the legal minimum.
A passive house goes much further. It is not a house that uses nothing, but one that needs so little heat that it no longer depends on a conventional heating system. We add two more layers. Circular: the materials can be recovered and reused. Regenerative: the house gives back energy, water, nature and stored carbon.
Below you will find each step, what it means in daily life and what it costs.
The house keeps the warmth in winter and the cool in summer. Very low energy use, steady comfort.
Reclaimed, natural and fixed so that they can be taken apart and reused.
It produces energy, keeps rainwater, makes room for nature and stores carbon.
Technology is not a fourth layer. It is what ties them together: the heat pump, the battery, the sensors.
1. What a passive house really is
The passive house, Passivhaus in German, is a standard developed in Germany. The first building, a row of four homes in Darmstadt-Kranichstein, has been lived in since October 1991, and the Passive House Institute, which certifies the standard today, was founded in 1996. It is not a product brand or an architectural style. It is a set of measurable criteria, checked by calculation at the design stage and by testing on site.
For cool-temperate climates such as Central Europe and most of Romania, three of the criteria say almost everything about comfort and energy use. All values refer to the heated floor area:
As an order of magnitude, at the limit of the standard: a house with 150 m² of heated floor area needs at most 2,250 kWh of heat per year. With an ordinary heat pump, that means around 750 kWh of electricity for heating, a small share of what a solar roof can produce in a year.
The standard also offers an alternative to the first criterion: a heating load of at most 10 W per m². At this level, the heat needed can be delivered through the fresh ventilation air itself. The house is heated largely passively, by the sun, the people and the appliances inside, and a very small system covers the rest.
Passive does not mean no energy use, nor no building services. The house still needs energy for hot water, cooking, lighting and appliances. The standard limits this total too: for the base class, at most 60 kWh per m² per year, counted as renewable primary energy. The envelope does most of the work, and the services stay small and easy to maintain.
The standard has three classes: Classic, Plus and Premium. Plus and Premium have stricter limits on energy use and also require on-site renewable generation, usually with solar panels. For renovations there is a separate version, EnerPHit.
2. Five principles, explained by how they feel
Continuous insulation
A thick, unbroken layer of insulation in the walls, the roof and under the slab, like a coat without holes.
How it feelsWalls and floors are almost the same temperature as the room air. No more cold corners or walls that feel chilly.
Triple glazing, well oriented
Windows with three panes of glass and insulated frames. Large glazed areas face south and catch the winter sun.
How it feelsYou can sit next to the window in winter without feeling cold air. Condensation on the inside of the glass practically disappears.
Airtightness
A continuous layer that seals the house like an envelope. It is checked on site with the airtightness test: the house is pressurised and the air that escapes is measured. Ideally the test is done once before the finishes, when leaks are still easy to fix, and once at the end.
How it feelsNo draughts, less dust and less noise from outside.
No thermal bridges
Details designed so that the insulation is not interrupted at the foundations, balconies, around windows or at fixings.
How it feelsCorners without stains or mould, because the inside surfaces stay warm and no longer collect condensation. The structure stays dry and lasts longer.
Ventilation with heat recovery
A small unit continuously brings fresh, filtered air into the rooms and removes stale air from the kitchen and the wet rooms. At least 75% of the heat in the outgoing air passes into the fresh air, without the two mixing. In living rooms, ventilation noise may not exceed 25 dB(A), which is barely audible.
How it feelsFresh air in the bedroom in the morning, with the windows closed. The filters hold back pollen and much of the fine dust.
Shading
Eaves, a porch or a pergola with plants block the high summer sun and let in the low winter sun. This is the rule that prevents overheating, and it matters a great deal in Romanian and Spanish summers.
The Loop house, element by element
Choose a layer to see what belongs to it. Tap a number or an explanation to find its match.
Swipe sideways to see the whole section →
- 1Continuous insulationin walls, roof and under the slab, without gaps
- 2Airtight layerchecked on site with the airtightness test
- 3Triple-glazed windowslarge to the south, small to the north
- 4No thermal bridgesthe insulation runs unbroken under the ground floor slab
- 5Ventilation with heat recoveryfresh, filtered air, with at least 75% of the heat recovered
- 6The porch gives shadeblocks the summer sun, lets the winter sun in
- 12Natural-fibre insulationwood fibre or cellulose in the roof
- 13Reclaimed brickfor the exposed masonry of the façades
- 7Integrated solar roofthe panels replace the roof covering
- 8Propane heat pumpnatural refrigerant, inside the outdoor unit
- 9Battery and bidirectional chargingthe electric car becomes an energy reserve
- 10Rainwater tankfor the garden and non-drinking uses
- 11Green façade and rain gardenshade, cooling, food and shelter for insects and birds
3. Circular: the house as a store of materials
A circular house is designed as a store of valuable materials, not as a future pile of rubble. Four simple rules:
- Reclaimed materials
- Brick from demolitions, reused timber, local stone. Every reused element avoids making a new one.
- Natural materials
- Untreated timber, wood fibre, cellulose, lime. Healthy indoors and easy to reuse at the end.
- Dry joints
- Elements fixed with screws and clips, not glued. A timber façade can be taken apart board by board, and the boards can be used again.
- Materials passport
- A list of every material, its quantity and where it was installed. The house also keeps the value of its materials.
Why it matters from 2028The European directive on the energy performance of buildings (2024/1275) requires the carbon footprint of new buildings to be calculated over their whole life cycle, from making the materials to demolition, and shown on the energy performance certificate: from 2028 for buildings over 1,000 m², from 2030 for all new buildings. The materials chosen today will be compared on this basis.
4. Regenerative: the house that gives back
A passive house uses little. A regenerative house goes a step further and leaves the place better than it found it.
It can produce more than it uses
Because a passive house uses so little, its solar roof can produce more energy than the house uses over the balance of a year. Production drops in winter, so the balance is made over the whole year, not day by day. The surplus goes to the battery, the electric car or the grid.
It keeps the rainwater
Water from the roof is collected in a buried tank and used for the garden and for uses that do not need drinking water. The overflow goes to the rain garden, a slightly lowered planted area that keeps the water in the ground instead of sending it to the sewer.
It makes room for life
Green façades with climbing plants, native species in the garden, built-in shelters for birds, bats and solitary bees.
It stores carbon
Timber and plant-fibre insulation keep the carbon the plants absorbed while growing. A timber structure holds it in the house for decades.
The biosolar roof: plants under the panels
On the flat roof of the Loop Twin house we propose a biosolar roof: solar panels mounted above a layer of vegetation. The plants cool the panels through evaporation, and the panels shade the plants. Panels produce less when they get hot, so the cooling matters.
A study by the University of Technology Sydney measured, on such a roof, solar output 3.6% higher, seven times more insect life and four times more bird life than on an ordinary solar roof. A more recent study by the same university, published in 2026, measured over four summer months 11.1% more output on average, with peaks above 23% on very hot days.
5. The technology that ties it together
- Propane heat pump
- Propane (R290) is a natural refrigerant with almost no climate impact. The European regulation on fluorinated gases (2024/573) bans, from 1 January 2027, placing on the market monobloc heat pumps up to 12 kW that use fluorinated gases with a high climate impact, and from 1 January 2032 those that use any fluorinated gas, with exceptions for safety. A monobloc propane heat pump installed outdoors already goes beyond these requirements. Propane is non-toxic but flammable. That is why, in these heat pumps, the whole refrigerant circuit sits in the outdoor unit, and the manufacturer specifies a safety zone around it with no windows, doors or sockets. The propane is not burned: it only carries heat, and the heat pump runs on electricity.
- Bidirectional charging
- The electric car becomes a large battery on wheels: it charges from the sun during the day and can power the house in the evening, where the car, the charger and the grid operator allow it.
- Sensors and control
- Temperature, humidity and CO2 sensors in the rooms. The ventilation, the heat pump and car charging run when there is sun and cheap energy. Everything is visible in one app.
6. The Loop and Loop Twin concept houses
In two concept houses, Loop and Loop Twin, we have brought all these layers together. The visualisations show the volume, the materials and the shading. The regenerative solutions described below are part of the concept, and the exact values are confirmed by calculation for each site, orientation and climate.


Loop · detached house
- Compact volume with a pitched roof. A small outer surface relative to the living space, so little heat is lost.
- Integrated solar roof. The panels replace the roof covering, and the skylight brings daylight into the middle of the house.
- Deep porch. It gives shade in summer and lets the sun in during winter, as in the section above.
- Light-coloured exposed masonry. It can be built from reclaimed brick.
- Green façade on the blank side wall. On the side wall without windows we propose climbing plants on cables.
- Electric car charging at the parking space, linked to the roof and the battery.


Loop Twin · two semi-detached homes
- Two homes, one shared wall. Each loses less heat than a detached house of the same size.
- Upper floor clad in timber boards. Mechanically fixed, easy to replace and reuse.
- Pergolas with deciduous climbing plants. Dense shade in summer; in winter the leaves fall and let the sun through.
- Biosolar roof. The flat roof receives vegetation with solar panels above it.
- Rainwater from both roofs, collected in a shared tank.
7. What it costs
Studies show building costs 2 to 10% higher than for an ordinary house:
- between 5 and 10% in European countries, according to a review of published studies carried out at Massey University;
- as little as 2% above the legal requirements in England, in a study by the Passivhaus Trust in the United Kingdom;
- around 3.5% on average, across 45 passive apartment buildings in New York State and Massachusetts.
The difference is decided almost entirely at the design stage. A compact form, simple details, windows of the right size, correct orientation. A house designed as passive from the first sketch costs a little more. A house designed conventionally and corrected later costs a lot more.
What you get in return: very low bills, the same temperature in every room, clean air and a house ready for the requirements coming in 2030.
8. What the law requires
All new buildings in the European Union must be nearly zero-energy buildings. In Romania, this applies to buildings received under a building permit issued from that date, and at least 30% of their energy must come from renewable sources: at least 10% from sources located on site and at least 20% certified renewable energy. In Spain, the minimum is set by the Building Technical Code (CTE, the DB-HE energy saving document), updated by Royal Decree 732/2019.
Directive 2010/31/EU · Romania, Law 372/2005 as amended · Spain, Royal Decree 732/2019New buildings owned by public bodies must be zero-emission buildings. For new buildings over 1,000 m², the life-cycle carbon footprint is calculated and shown on the energy performance certificate.
Directive (EU) 2024/1275All new buildings must be zero-emission buildings, meaning very low energy use, covered by renewable sources, with no on-site emissions from fossil fuels. The carbon footprint is calculated for all of them.
Directive (EU) 2024/1275
The conclusion: a house designed today only to the nZEB minimum will fall below the standard required of new buildings within a few years. A passive regenerative house is designed for that standard from the start.
| nZEB | Passive house | Passive regenerative house | |
|---|---|---|---|
| What it is | Legal minimum across the EU | Voluntary, certified standard | The Cerc approach |
| Heating demand | Limits set by each country's national method | At most 15 kWh per m² per year | As for the passive house |
| Renewable energy | Set nationally (in Romania, at least 30%) | On-site generation required in the Plus and Premium classes | Production above annual use, as a design target |
| Materials | Not taken into account | Not taken into account | Reclaimed, natural, demountable |
| Water and nature | Not taken into account | Not taken into account | Rainwater, green façades, biosolar roof |
9. What to ask your design team for
Whoever you work with, these documents show whether a house is truly designed as passive or only promised as such. They are worth writing into the contract.
- The full energy calculation of the house, for example in the Passive House Institute software (PHPP), not just the energy performance certificate.
- Construction details for the critical junctions: foundations, windows, roof, balconies, service penetrations.
- The airtight layer plan, drawn on every plan and section, and the airtightness test written into the contract.
- The ventilation design, with airflows per room and the noise level.
- The summer comfort check and the shading solution for each façade.
- The materials list, with their origin and how they can be taken apart.
- The solar production estimate and the energy balance over a year.
- A site inspection plan: who checks, when, and what is photographed before it is covered up.
10. Frequently asked questions
Does a passive house use no energy at all?
It does use energy, just very little. The standard limits the heating demand to 15 kWh per m² per year and the total use of the house, meaning heating, hot water and appliances, to 60 kWh per m² per year for the base class, counted as renewable primary energy. For the yearly balance to reach zero or go positive, the house has to produce its own energy, usually with solar panels. The Plus and Premium classes require even lower use as well as on-site renewable generation.
What is the difference between nZEB, a passive house and a zero-emission building?
nZEB is the legal minimum for new buildings across the EU since the end of 2020, defined in detail by each country. A zero-emission building is the European standard required for all new buildings from 2030 and for public ones from 2028: very low energy use, covered by renewable sources, with no on-site emissions from fossil fuels. The passive house is a voluntary, certified standard that cuts energy demand as far as possible. Because it starts from very low demand, it is a direct path to zero emissions.
How is it heated, in practice, and what happens on very cold days?
The heating power needed is in the order of 10 W per m², about 1.5 kW for a 150 m² house. A small heat pump is usually enough, often the same one that heats the hot water. Heat can be delivered through the ventilation air, the floor or a few radiators. The calculation uses the local climate data, including the coldest days.
Does such a well-insulated house overheat in summer?
Not if it is designed properly, and the standard checks this: the indoor temperature may exceed 25 °C for at most 10% of the time. This comes from orientation, external shading, correctly sized windows and night-time airing. In warm regions such as southern Romania and Spain, the heat pump can also cool, and the standard limits the cooling demand too.
Is a propane heat pump safe?
Yes, when installed correctly. Propane (R290) is non-toxic but flammable. Propane heat pumps for houses are usually monobloc units: the whole refrigerant circuit sits in the outdoor unit and only water enters the house. The manufacturer specifies a safety zone around the unit, with no windows, doors or sockets, and the units follow the European standards for flammable refrigerants. The propane is not burned: it only carries heat, and the heat pump runs on electricity.
Is the ventilation noisy, or does it dry out the air?
In living rooms, ventilation noise may not exceed 25 dB(A), which is barely audible. Dry winter air is avoided by correctly calculated airflows, around 30 m³ per hour per person and no more. Where needed, units that also recover part of the moisture, not just the heat, are used.
Can a passive house be built in brick or concrete blocks, not only timber?
Yes. The standard does not prescribe a material, only measurable results. There are passive houses in masonry, concrete, timber or mixed construction. What matters is continuous insulation, details without thermal bridges and an airtight layer planned from the start.
Can an existing house be upgraded?
Yes. For renovations there is the EnerPHit standard, created by the same institute, with requirements adapted to existing buildings. The order of works matters: envelope and windows first, then airtightness, then ventilation and the heat pump. The works can also be done in stages, following a plan set from the start, so that each stage prepares the next.
Does the house need to be certified, and what do you actually receive?
Certification is not mandatory. It is carried out by a certifier accredited by the Passive House Institute, based on the energy calculation of the house and the airtightness test, and it is a useful guarantee when selling or financing. Even without a certificate, it is worth receiving two documents at the end: the calculation showing the expected energy use and the airtightness test report.
