An ordinary house loses heat in five ways: through the walls and roof, through the windows, through gaps, through poorly insulated corners and junctions, and through the warm air we let out when we air the rooms.
A passive house closes all five. Scroll down: with each principle, the drawing closes one more way out.
The ordinary house
The arrows show where the heat goes in winter. Every way that is closed means less energy for heating and more comfort.
Continuous insulation
The walls, roof and floor slab are wrapped in a thick layer with no gaps. The Passive House Institute guidelines recommend that each square metre loses no more than 0.15 watts for every degree of difference between inside and outside. In detached houses, the value is often below 0.10.
Walls are almost the same temperature as the room air.
Triple glazing, facing south
The whole window, frame included, loses no more than 0.80 watts per square metre for every degree, and no more than 0.85 once installed in the wall. Large windows face south and let in the winter sun. Those facing east and west get shading, so the house does not overheat in summer.
Even on cold nights, the inside of the glass stays above 17 °C. You can sit by the window without feeling cold.
Airtightness
A continuous layer seals the house like an envelope. On site, the airtightness test is carried out: the house is pressurised and the air that escapes is measured. At 50 Pa, leakage must be no more than 0.6 times the volume of the house per hour.
No draughts, less dust and less noise from outside.
No thermal bridges
Corners, balconies, foundations and fixings are where heat escapes most easily. Here they are designed so that the insulation runs without a break. A balcony, for example, is fixed with a part that interrupts the flow of heat.
Corners without stains or mould, because the inside surfaces stay warm.
Ventilation with heat recovery
A small unit continuously brings in fresh air and removes stale air. At least 75% of the heat in the outgoing air passes into the fresh air. Without heat recovery, ventilation alone could lose around 24 kWh per square metre a year, more than all the heating a passive house is allowed.
Fresh air with the windows closed, and the unit is no louder than 25 dB(A) in living rooms.
Shading
Eaves or a porch block the high summer sun and let in the low winter sun. The standard requires the indoor temperature to exceed 25 °C for no more than 10% of the time.
With all five ways closed, the house needs at most 15 kWh per square metre a year for heating. For a 150 m² house, the heating power needed is in the order of 1.5 kW, and a small heat pump is enough.
True or false?
A passive house has to be built from timber.
False. The standard does not prescribe a material. There are passive houses in masonry, concrete, timber or mixed construction.
The large windows go on the north side, so that not too much sun gets in.
False. The large windows face south, so the sun gets in during winter. In summer, shading protects them.
Without heat recovery, airing alone would use more than all the heating allowed.
True. Ventilation without heat recovery can lose around 24 kWh per m² a year, while the limit for heating is 15.